Los Angeles Drywall & Framing logo
About
Process
Gallery
Services
Not sure what you need?Describe it and we'll point you right
Drywall InstallationBoard hung fast and hung straightDrywall RepairHoles, cracks and water damage undoneDrywall FinishingTaped and sanded up to Level 5Drywall TexturingKnockdown, orange peel and skip trowelDrywall PatchingSmall holes gone without a traceFire Rated Drywall InstallationType X and Type C to the listingSoundproof Drywall InstallationAssemblies built to a target STCMold Resistant Drywall InstallationBoard that survives wet roomsImpact Resistant Drywall InstallationCorridors that shrug off cartsDrywall DemolitionClean removal with the dust contained
All drywall services

Licensed, Bonded & Insured — CA Lic. #1141917

View all 45 services
Service Areas
Don't see your area?We probably cover it. Ask us.
Beverly HillsEstate finishes and hillside permitsWest HollywoodDense rentals and design district TIHollywoodStages, studios and historic coresDowntown LAHigh rise shafts and office TISanta MonicaCoastal permits and soft story retrofitsPacific PalisadesFire rebuilds under the 2026 codeMalibuCoastal Commission and salt airBrentwoodCanyon lots and Level 5 finishesCulver CityCreative office and studio buildouts
All Los Angeles areas

Licensed, Bonded & Insured — CA Lic. #1141917

View all 25 areas
FAQ
Contact
(310) 730-9832Get Free Estimate
DensGlass fiberglass mat gypsum sheathing installed on a steel stud exterior wall in Los Angeles
Fiberglass Mat Sheathing

DensGlass Sheathing Installation in Los Angeles, CA

DensGlass sheathing is a fiberglass mat faced gypsum panel screwed to exterior stud framing as the substrate that carries the weather barrier and the cladding above it. We work as a DensGlass contractor on steel stud backup walls, exterior soffits, and behind stucco throughout Los Angeles. Architects specify it on Westside podium buildings, Downtown infill, and Valley mixed use projects because the glass mat face does not wick water or delaminate the way a paper face does when a job sits open through a wet January. Our crews handle layout, fastening, joint treatment, and the inspection sequence that follows.

Request a DensGlass Bid
Close view of DensGlass sheathing joints and screw spacing on an LA exterior wall

Glass Mat Face, Screwed Tight

Los Angeles, CA

Product Specific Work

What a DensGlass Installer Actually Delivers on an LA Wall

DensGlass Sheathing is manufactured by Georgia-Pacific to ASTM C1177, the specification covering glass mat gypsum substrate for use as sheathing. The distinction that matters on a Los Angeles jobsite is the facing. A conventional paper cover sheet absorbs water and separates from the core once it stays wet, while the fiberglass mat embedded in this panel offers neither the organic food source nor the same bond failure path. Georgia-Pacific warrants the panel against delamination and deterioration through up to twelve months of normal weather exposure during construction, which is why it survives the long gap many projects here have between dry in and cladding.

The panel also carries the test data California plan check asks for. It is noncombustible when tested to ASTM E136, and it reports a flame spread and smoke developed rating of 0 and 0 under ASTM E84. It scores a 10 under ASTM D3273, the highest result in that mold growth test. Those three data points are why DensGlass appears in Very High Fire Hazard Severity Zone submittals across the Santa Monica Mountains and the foothills, and in exterior wall assemblies now governed by the California Wildland-Urban Interface Code, Title 24 Part 7, effective January 1, 2026, which absorbed the former Chapter 7A provisions.

Installation is where the product either performs or does not. We set panels across steel C studs spaced no more than 24 inches on center, drive corrosion resistant screws no closer than three eighths of an inch from ends and edges, and hold consistent eight inch spacing at edges and at intermediate framing. Joints and fastener heads get treated per ASTM C1280 or GA-253 before anything covers them. On a Los Angeles project the sheathing is also the plane the waterproofing consultant photographs, so we leave it clean, tight, and ready for the next trade rather than patched after the fact.

Where It Goes

DensGlass Exterior Wall, Soffit and Stucco Substrate

DensGlass Exterior Wall Sheathing

On steel stud backup walls the sheathing is the first continuous plane on the building, and every trade after us works off it. We run panels tight to the framing, keep board edges landing on stud flanges rather than floating in the bay, and stagger courses so no four corners meet. Openings get cut from the panel rather than pieced at the jamb, because a butt joint at a window corner is where cracking starts. Fastener heads are set flush, never overdriven through the mat.

DensGlass Soffit and Overhang Framing

Exterior soffits at balconies, breezeways, and drive through entries need a substrate that will not sag or grow mold in an unconditioned cavity. We hang glass mat panels on furring or hat channel at the spacing the design calls for, add framing where the layout leaves an unsupported edge, and detail the perimeter so the soffit ties into the wall plane instead of stopping short of it. For LA properties in wildfire zones the soffit assembly also has to answer the ignition resistance provisions written for enclosed eave undersides.

DensGlass Behind Stucco

California Building Code Chapter 25 does not allow gypsum board as a direct backing for cement plaster. It is permitted with a water resistive barrier as backing for self furred metal lath, which is exactly how DensGlass is used behind stucco in Los Angeles. We install the sheathing as the rigid substrate, coordinate the barrier lap sequence with the waterproofing scope, and leave a surface the lath contractor can furr and tie to without shimming it flat. ASTM C1063 requires that barrier in place over the sheathing before any lath goes up.

Completed DensGlass sheathing elevation ready for weather barrier in Los Angeles
Close view of DensGlass sheathing joints and screw spacing on an LA exterior wall

ASTM C1177 Compliance

Every panel we install under this scope is a glass mat gypsum substrate meeting ASTM C1177, and we keep the submittal package, the Intertek code compliance research report, and the manufacturer technical data on file for the project record. Substitutions are not made at the yard counter to save a delivery day. When an inspector, a lender consultant, or an owner rep asks what sits behind the cladding, the paperwork matches the wall.

Exposure Tracking

The twelve month exposure allowance is a limit, not a schedule. We date stamp the dry in, flag panels approaching the end of the window, and tell the general contractor in writing when a delayed cladding package is putting the manufacturer warranty at risk. On stalled Los Angeles projects that written record has saved owners the cost of tearing off and resheathing an entire elevation late in the job.

DensGlass fiberglass mat gypsum sheathing installed on a steel stud exterior wall in Los Angeles
Specifications

DensGlass Installation Specifications

The numbers below are the ones our foremen check on every elevation before the wall is released to the weather barrier trade.

Panel Standard
ASTM C1177, glass mat gypsum substrate for use as sheathing. This is a different specification from the one covering paper faced gypsum sheathing.
Framing Spacing
Steel C studs at a maximum of 24 inches on center for standard panel application, tightened where wind load or the structural engineering calls for it.
Fasteners
Corrosion resistant drill screws meeting ASTM C954 for steel from 0.033 to 0.112 inch thick, or ASTM C1002 type S screws for lighter gauge framing.
Screw Spacing
Eight inches on center at panel edges and at intermediate framing, with every fastener held no closer than three eighths inch from ends and edges.
Joint Treatment
Joints and fastener heads treated in accordance with ASTM C1280 or GA-253 before any weather barrier, lath, or cladding is applied over the panel.
Verified Test Data
Noncombustible per ASTM E136, flame spread and smoke developed of 0 and 0 per ASTM E84, a score of 10 under ASTM D3273, and twelve months exposure.
Our Process

How We Sheathe a Building in DensGlass

Five stages from submittal to sign off, run the same way on a Culver City office shell as on a hillside residence above Sunset.

1

Submittal and Elevation Takeoff

We review the elevations and wall types, confirm which panel thickness each assembly calls for, and submit product data and the code report for approval. Takeoff runs elevation by elevation so panel orientation, opening locations, and control joint positions are settled on paper. Conflicts between our scope and the waterproofing specification go out as an RFI before material is ordered.

2

Framing Verification

Before the first panel goes up we walk the backup framing and check stud spacing, flange alignment, and whether every panel edge will land on steel. We look for twisted studs, missing bridging, and openings framed off the schedule, because none of that improves once it is covered. Where the framing plane runs out we shim or respace rather than forcing board across a hollow.

3

Panel Layout and Hanging

Panels are set with joints staggered and edges bearing on framing, cut around openings rather than butted at corners, and held off adjacent materials where the detail calls for a gap. Crews work from a marked layout so orientation stays consistent up the elevation. On tall walls we sequence with the swing stage schedule so no elevation sits half sheathed through a rain event.

4

Fastening and Joint Treatment

Screws are driven to the specified pattern with the head flush and the glass mat intact, and any overdriven fastener is backed out and replaced beside the original. Once the elevation is fastened off, joints, corners, and fastener heads are treated to the ASTM C1280 or GA-253 requirement. Openings and dissimilar material junctions get treated in the same pass.

5

Handoff and Exposure Control

We photograph the finished elevation, log the dry in date, and hand the wall to the weather barrier and cladding trades with joint treatment complete. If the follow on scope is delayed we monitor the exposure clock and notify the general contractor before the allowance runs out. Punch items are corrected on our own crew time rather than left for the next subcontractor.

Work That Goes With This

Services That Pair With DensGlass Sheathing Installation

DensGlass rarely arrives alone. These are the scopes that sit directly above and below it on a Los Angeles exterior wall.

Exterior Gypsum Sheathing services by Los Angeles Drywall & Framing

Exterior Gypsum Sheathing

Exterior gypsum sheathing per ASTM C1177, including fire rated and moisture resistant boards, installed as the weather-barrier substrate on steel stud backup walls.

View Service
Tall Wall Metal Framing services by Los Angeles Drywall & Framing

Tall Wall Metal Framing

Tall exterior steel stud walls and curtain wall backup framing engineered for wind load and L/240 or L/360 deflection limits at heights beyond standard stud tables.

View Service
Stucco Lath Installation services by Los Angeles Drywall & Framing

Stucco Lath Installation

Metal lath and stucco mesh installed over two layers of weather-resistive barrier with correct furring, laps, and fastening so the plaster has a code-compliant key.

View Service
Cold Formed Steel Framing services by Los Angeles Drywall & Framing

Cold Formed Steel Framing

Cold formed steel framing engineered to AISI S100 and S220. Stud and track systems, bridging, and load-bearing assemblies from 33 mil through 97 mil.

View Service
Service Area

Where We Provide DensGlass Sheathing Installation

We sheathe exterior walls, soffits, and stucco substrates across the LA basin, the Westside, the San Fernando Valley, and the South Bay.

Central Los Angeles

  • Beverly Hills
  • West Hollywood
  • Hollywood
  • Downtown LA

Westside & Beach Cities

  • Santa Monica
  • Pacific Palisades
  • Malibu
  • Brentwood
  • Culver City

San Fernando Valley

  • Burbank
  • Glendale
  • Sherman Oaks
  • Studio City
  • North Hollywood
  • Encino
  • Van Nuys

Foothill Communities

  • Pasadena
  • Altadena

South Bay & Long Beach

  • Manhattan Beach
  • Torrance
  • Long Beach

Orange County

  • Irvine
  • Newport Beach
  • Costa Mesa
  • Huntington Beach
Common Questions

DensGlass Sheathing Questions

What is the difference between DensGlass and regular gypsum sheathing?
The core is gypsum in both cases. The difference is the facing and the standard behind it. DensGlass is a fiberglass mat faced panel made to ASTM C1177, while traditional gypsum sheathing uses a paper cover sheet. Paper absorbs water and delaminates from the core when it stays wet, and it gives mold an organic surface to grow on. The glass mat does neither, which is why this panel carries a twelve month construction exposure allowance and a top score of 10 under ASTM D3273 mold resistance testing.
How long can DensGlass sheathing stay exposed before the cladding goes on?
Georgia-Pacific covers up to twelve months of normal weather exposure during construction under its limited warranty against delamination and deterioration. That is a construction period allowance, not a permanent finish rating, and it assumes the panels were installed and treated correctly. On Los Angeles projects that stall between dry in and cladding we track the exposure date by elevation and put the general contractor on notice in writing as the window closes, so the decision to accelerate or resheathe is made deliberately rather than discovered at closeout.
Can DensGlass be used as a substrate behind stucco?
Yes, and it is one of the most common uses for it in Los Angeles. California Building Code Chapter 25 prohibits gypsum board as a direct backing for cement plaster, but permits it with a water resistive barrier as backing for self furred metal lath and cement plaster. The sequence is sheathing, barrier, lath, then plaster. ASTM C1063 requires the barrier over the sheathing before lath is applied. We coordinate the lap and flashing details with whoever holds the waterproofing scope so no layer is installed out of order.
What screws and spacing do you use on steel studs?
For steel framing from 0.033 to 0.112 inch thick we use corrosion resistant drill screws meeting ASTM C954, and for lighter gauge framing self piercing tapping screws meeting ASTM C1002. Spacing is eight inches on center at panel edges and at intermediate framing, with every fastener held at least three eighths of an inch back from ends and edges so the screw does not blow out the corner. Heads are set flush with the mat. An overdriven screw that tears the mat is replaced beside the original hole.
Do you install DensGlass on exterior soffits and eaves?
We do. Exterior soffits at balconies, entry canopies, and drive throughs are unconditioned, humid, and hard to reach later, which makes a glass mat panel the sensible substrate. We hang board on framing or hat channel at the spacing the design requires and add support wherever the layout would leave an unsupported panel edge. For properties in Los Angeles wildfire zones the enclosed eave underside also has to satisfy the ignition resistance provisions in the California Wildland-Urban Interface Code.
Does DensGlass count as a noncombustible material for fire zone plan check?
DensGlass Sheathing is noncombustible as tested in accordance with ASTM E136, and it reports a flame spread index and smoke developed index of 0 and 0 under ASTM E84. That data is frequently what supports its use in exterior wall assemblies in Very High Fire Hazard Severity Zones. What it does not do on its own is make an assembly compliant. The Wildland-Urban Interface Code sets requirements for the whole exterior wall, covering, eaves, vents, and glazing, so the sheathing is one verified component inside a larger approved assembly.
Get In Touch

Request a Free
Estimate

We are ready to bring your project to life. Reach out for a free estimate on your drywall, framing, or specialty project. Our team responds within 24 hours.

Office LocationLos Angeles, CA
Business HoursMon-Fri: 8AM to 6PM, Sun: Open
Call Us(310) 730-9832
Email Ussales@losangelesdrywallandframing.com

Request Your Free Estimate

Los Angeles Drywall & Framing logo

Licensed drywall contractor and framing specialist serving Los Angeles, CA and the surrounding metro area. Quality craftsmanship for residential and commercial projects. CA License #1141917.

(310) 730-9832sales@losangelesdrywallandframing.com
Los Angeles, CA

Services

Drywall Services
  • Drywall Installation
  • Drywall Repair
  • Drywall Finishing
  • Drywall Texturing
  • Drywall Patching
  • Fire Rated Drywall Installation
  • Soundproof Drywall Installation
  • Mold Resistant Drywall Installation
  • Impact Resistant Drywall Installation
  • Drywall Demolition
Framing & Metal Stud
  • Wall Framing
  • Residential Framing
  • Commercial Framing
  • Rough Carpentry
  • Custom Framing
  • Rough Opening & Header Framing
  • Chase Wall & Bulkhead Framing
  • Fire Rebuild Construction
  • Metal Framing
  • Cold Formed Steel Framing
  • Deflection Track Installation
  • Steel Stud Partition Installation
  • Tall Wall Metal Framing
  • Metal Framed Ceiling Installation
  • Hat Channel Installation
  • Resilient Channel Installation
Stucco, Paint & Sheathing
  • DensGlass Sheathing Installation
  • Exterior Gypsum Sheathing
  • Stucco
  • Stucco Patching
  • Stucco Lath Installation
  • Stucco Waterproofing
  • Stucco Removal & Remediation
  • Exterior Painting
  • House Painting
  • Interior Painting
Commercial & Multi-Family
  • Commercial Metal Stud Framing
  • Commercial Wood Framing
  • Commercial Stucco
  • Commercial Painting
  • Multi-Family Drywall
  • Multi-Family Metal Stud Framing
  • Multi-Family Wood Framing
  • Multi-Family Stucco
  • Multi-Family Painting

Service Areas

Central LA & Westside
  • Beverly Hills
  • West Hollywood
  • Hollywood
  • Downtown LA
  • Santa Monica
  • Pacific Palisades
  • Malibu
  • Brentwood
  • Culver City
San Fernando Valley
  • Burbank
  • Glendale
  • Sherman Oaks
  • Studio City
  • North Hollywood
  • Encino
  • Van Nuys
South Bay & Foothills
  • Pasadena
  • Altadena
  • Manhattan Beach
  • Torrance
  • Long Beach
Orange County
  • Irvine
  • Newport Beach
  • Costa Mesa
  • Huntington Beach

Company

  • Home
  • About
  • Process
  • Gallery
  • FAQ
  • Contact

© 2026 Los Angeles Drywall & Framing. All rights reserved.

Privacy PolicySitemap